page 1Review action

Returned No Exceptions Taken. Rated capacity 3,500 pounds and rated speed 800 feet per minute as specified. Ride quality data submitted shows 12 milli-g horizontal and 15 milli-g vertical at contract speed, within the limits of 08 44 13 [sic, 14 21 00] paragraph 2.09.

page 2Acceptance test scope

Final acceptance testing to include safety device operation, buffer test, governor trip speed, brake test at 125 percent of rated load, emergency power transfer and recall, and a five hour continuous run at rated load. The Owner's independent elevator consultant to witness.

Cross references

DirectionRelationDocumentNote
this →reviewed against14 21 00 Electric Traction ElevatorsElevator data reviewed against 14 21 00