Corbel
← The project record
Specification

14 21 00

Electric Traction Elevators

spec_142100_r1.pdf · 29 pages · issued Jul 2, 2025 by Lindeman Vertical · Vertical Transportation · revision 1

Indexed passages

page 914 21 00 - 1.08Performance, speed and capacity

Passenger elevators in bank A shall have a rated capacity of 3,500 pounds and a rated speed of 800 feet per minute. Contract speed shall be maintained within 3 percent under any loading condition from empty to rated load in either direction of travel. Floor to floor time for a single storey run of 10 feet 6 inches, measured from start of door close to completion of door open, shall not exceed 8.5 seconds.

page 1514 21 00 - 2.09Ride quality

Horizontal vibration shall not exceed 15 milli-g peak to peak in either horizontal axis and vertical vibration shall not exceed 18 milli-g peak to peak, measured in accordance with ISO 18738 at contract speed. Sound pressure level inside the car shall not exceed 55 dBA during travel with the ventilation fan running.

page 2414 21 00 - 3.05Final acceptance testing

Perform a full load, full speed test of each elevator in the presence of the Owner's representative and the Owner's independent elevator consultant. Testing shall include safety device operation, buffer test, governor trip speed, brake test at 125 percent of rated load, emergency power transfer and recall sequence, and a five hour continuous run at rated load with no faults.

Cross references

DirectionRelationDocumentNote
→ thisreviewed againstSUB-142100-01 Elevator equipment data, bank AElevator data reviewed against 14 21 00