Returned Revise and Resubmit. The lobby mullion shown at detail 4 on sheet S-12 is a 10 inch depth and calculates to a deflection of 1.63 inches at design wind load, exceeding the permissible 1.317 inches for the 21 foot 4 inch clear span under 08 44 13 paragraph 1.07. Increase the mullion depth or add an intermediate structural support and resubmit calculations sealed by a Florida registered engineer.
← The project record
Submittal
SUB-084413-02
Curtain wall shop drawings, east and north elevations
sub_sub_084413_02.pdf · 3 pages · issued Oct 29, 2025 by Cordova Glass Systems · Architectural · revision 1
Indexed passages
page 1Review action
page 2Glazing schedule
Typical vision unit: 6 mm heat strengthened outboard with low emissivity coating on surface two, 12 mm argon filled cavity, 6 mm heat strengthened inboard. Spandrel unit: 6 mm heat strengthened outboard with ceramic frit on surface two over a 12 mm cavity and 6 mm heat strengthened inboard with insulated back pan.