Raise the parapet at the north elevation between column lines 6 and 11 by 4 inches to provide the 8 inch minimum base flashing height required by specification 07 52 00 paragraph 3.04. Revised detail 7/A-501 attached. This ASI clarifies the Contract Documents and is issued at no change in Contract Sum and no change in Contract Time. Proceed with the work as revised.
← The project record
ASI
ASI-006
Revised parapet detail, north elevation
asi_006.pdf · 4 pages · issued Jun 13, 2026 by Ardent Architects · Architectural · revision 0
Indexed passages
page 1Description of change
page 3Attached details
Detail 7/A-501 revision 2, parapet section at north elevation, showing the raised concrete masonry parapet, revised coping, and continuity of the air barrier from the wall assembly to the roof membrane at the raised height.
Cross references
| Direction | Relation | Document | Note |
|---|---|---|---|
| this → | answers | RFI-014 Parapet height at north elevation less than specified base flashing height | ASI-006 issued in response to RFI-014 |
| → this | priced by | CO-014 Parapet raise, north elevation | CO-014 submitted against ASI-006 |
| → this | references | OAC-2026-31 Owner Architect Contractor meeting number 31 | Meeting minutes record completion of the ASI-006 parapet raise |